Bosch Motorsport
2.
Drag the 'Hysteresis' computed source from the Toolbox and drop it on 'Computed
Channels' in the C 60 Project Tree. A 'Hysteresis Wizard' opens.
a) Choose input measurement channel.
b) Choose unit group and unit of output.
c) Enter output value of state A in the unit selected in b).
d) Enter threshold value when state changes from A to B.
e) Enter delay time when state changes from A to B.
f) Enter output value of state B in the unit selected in b).
g) Enter threshold value when state changes from B to A.
h) Enter delay time when state changes from B to A.
i) Enter time when the hysteresis function is activated after vehicle's startup.
j) Enter the channel's state (A or B) at startup.
3.
Click 'Next' when done. The second part of the 'Hysteresis Wizard' opens.
4.
Click 'Finish' when done.
5.
Enter channel name and description.
Data_Logger_C_60_Manual
Analog and Frequency Inputs | 9
53 / 100