Strata CTX100 Installation

Environmental Considerations

Table 2-1
provides a summary of the environmental characteristics.
Table 2-1
CTX100 Environmental Characteristics
Environmental Specifications
Operating temperature
Operating humidity
Storage temperature
BTU Rating (Base plus Expansion Cabinet)
ACTU (installed)
BDKU (5 installed)
RCOU/RCOS (1 installed)
Digital Telephones (40 installed)

AC Power and Earthing Requirements

The CTX100 requires an earth connection back to the main distribution point for proper operation and
safety. Failure to provide this earth may be a safety hazzard or lead to confusing fault, or operational
symptoms and,in extreme cases, system failure. The AC power cord already contains a conductor for
the "protective earth" provided by the commercial power outlet. This alone is not sufficient. It is also
necessary to connect a seperate insulated conductor between the Frame Ground (FG) terminal on the
base KSU and the main distribution point. (See
the general rules for earthing contained in BS6701 parts 1 & 2.
Note
Please note, no plug is fitted to the European version of CTX100 Product. Please refer to
the chapter 'Notes to Users' at the end of this manual, which defines the power
connection method.
Electrical Building
Ground (Main Power
Distribution Box)
Figure 2-2
Lack of proper ground may cause improper operation and, in extreme cases, system
CAUTION!
failure.
2-4
32~104° F (0~40° C)
20~80% relative humidity without condensation
-4~140° F (-20~60° C)
190 Watts (56 watt hours for both cabinets)
Figure
Fused Spur
Third Wire
AC Ground
135cm (4' 5")
A
AC Voltage
220-240VAC
AC Current
1 amp max.
CTX100 Grounding Diagram
2-2). This must be installed in accordance with
Expansion cabinets are NOT terminated
with plugs and must be hardwired to
a fused spur.
CTX 100 Base Cabinet
Power
Supply
Alternate Ground
5911ctx
Strata CTX I&M September 2002