Flash Output Sync Signal - Panasonic MICRO-IMAGECHECKER A200 Series Hardware Manual

Machine vision system
Hide thumbs Also See for MICRO-IMAGECHECKER A200 Series:
Table of Contents

Advertisement

Input/Output Terminals (Input/Output Ports)
3.5

Flash Output Sync Signal

3.5

Flash Output Sync Signal

Terminal Positions
Output Circuit
Use the output controller parallel output (NPN specification) circuit within the ranges
illustrated below. (Maximum 24mA for 1 Signal)
NPN output controller output circuit
Rated operating voltage:
5 V to 24 V
Flash Timing Chart
Flash output
signal
NPN output controller: A+B+C
Photo−Mos output controller: A+B+C
A: Imagechecker flash output sync signal lag. This
value changes depending on what type of
strobe is attached.
B: Strobe response time. Determined by the
strobe.
C: Strobe flash time. Determined by the strobe.
3 − 8
COM
FLASH
Photo−mos controller output circuit
Output
COM
(–)
Rated operating voltage:
5 V to 24 V
550µs/450µs
Around 63µs(1H)
COM:
The flash terminal is located
in the output terminal.
FLASH: The common terminal for use by
the flash is a specialized
terminal. Do not use it together
with other common lines.
Use within the range specified below
Output
Current
load (mA)
COM
(
)
±
Externally supplied power voltage (V)
Standard voltage: 5 V to 24 V DC
OFF
In the case on the NPN output
controller, use a flash for which
the time from when the flash
output synchronization signal
goes on to when the light gen-
eration finishes is 550μs or
550µs
less. For the Photo−MOS con-
450µs
troller, use a flash for which this
time is 450μs or less.
A strobe can only be used for
the
ANM830A camera in frame
mode.
A200/A100 Hardware
5
5
flash
output
for
the

Hide quick links:

Advertisement