A200/A100 Hardware
2.1

Connecting Peripherals

Be sure to connect peripherals to the controller only when the controller power is OFF.
24 V DC
Ground
*Only one camera can be connected to the A100.
Using Peripherals Correctly
− Do not connect products not specified by us to the controller.
− Be sure to connect peripherals only when the controller power is turned OFF.
Otherwise, damage could result.
− When you connect multiple cameras to an A200 controller be sure the cameras are
of the same type.
− When you connect only one camera to an A200 controller plug it in to the Camera
A jack.
− Avoid unintentional cable detachment by arranging the wiring so there is no weight
or load on the cable connector joints.
− When unplugging a connector, be sure to grasp the connector part itself and avoid
exerting unnecessary force on the cable. Also, avoid touching or allowing water to
come in contact with the connector pins.
Installation and Wiring
2.1

Connecting Peripherals

Keypad
Monitor−Cable
Camera−Cable
2 − 3