HP 11757B Installation And Calibration Manual page 31

Multipath fading simulator
Hide thumbs Also See for 11757B:
Table of Contents

Advertisement

HP 11757B
Note
parameters are set to 45 MHz and 95 MHz, but
sweep is set to o .
FREQ = 70 MHz
Start Sweep = 45 MHz
Stop Sweep = 95 MHz
DEPTH = 0 dB
ATTEN = 0 dB
3. Connect the output of the signal generator to the
IF Input of the Fader. Use a 75 cable, with an
adapter at the synthesized sweeper output.
Use Video Trigger on the spectrum analyzer to set a
stable trace.
4. Connect the IF Output of the Fader to the input of
the spectrum analyzer. Use a 75 cable with an
adapter at the spectrum analyzer.
5. Set notch depth to 20 dB.
Press
4
NOTCH DEPTH
Press
4
5 4
5 4
2
0
Figure 1-7. Front Panel Checks Setup
Installation and Calibration
5
5
ENTER
23