Installation
Self Tests
JITTER Test (test time- approximately 20 minutes)
These tests apply to HP 37718A option 204, 205, 206 only. Provides extensive tests
of the PDH/SDH Tx/Rx Jitter sections. Note this test is run as part of ALL TESTS.
Subtest
Test Function
1-50
Jitter Receiver Internal Loopback tests
51-100
Not used
101
STM-16 Optical Power Check
102
Not used
103-108
2Mb/s Tx/Rx Jitter Tests
109-114
8Mb/s Tx/Rx Jitter Tests
115-120
34Mb/s Tx/Rx Jitter Tests
121-126
140Mb/s Tx/Rx Jitter Tests
127-150
Not used
151-156
STM1e Tx/Rx Jitter Tests
157-162
STM1o Tx/Rx Jitter Tests
163-168
STM-4 Tx/Rx Jitter Tests
169-174
STM-16 Tx/Rx Jitter Tests
175-177
Wander Tests
178
Transfer Test 155 Electrical
179
Transfer Test STM-16
LONG GATING test (test time- approximately 6 Hours)
This test performs an extended gating check of each SDH/SONET Optical rate to
confirm error free operation. Test time at each rate is sufficient to ensure that the
error ratio is less than 1 in 10^12. The test does NOT form part of ALL TESTS.
Subtest
Test Function
1
Tx/Rx STM-0o with Bulk 2^23 Payload
2
Tx/Rx STM-1o with Bulk 2^23 Payload
3
Tx/Rx STM-4o with Bulk 2^23 Payload
4
Tx/Rx STM-16o with Bulk 2^23 Payload
5-6