HP 37718A Installation And Verification Manual page 155

Hide thumbs Also See for 37718A:
Table of Contents

Advertisement

Performance Tests
SDH Transmit/Receive Jitter Amplitude Accuracy
STM-4 Optical
49 Change Transmit/Receive Rate to STM-4 Optical with AU4-4C Mapped Bulk
Filled 2^23 PRBS Payload. Check and adjust the optical power as necessary.
Ensure Jitter is OFF and Calibration Pattern is OFF, then repeat steps 6 to 43
using the information in the Table below for STM-4.
STEP
TX
RX
Range
Range
6-8
OFF
1.6UI
9
OFF
1.6UI
13-15 20
1.6UI
16-20
22-25
27-31
16UI
33-37
39-43 200
256
RX
Tx
Tx
Filter
UI p-p
Freq
LP+HP2 OFF
OFF
LP+HP1 OFF
OFF
LP+HP1 0.2
250K
LP+HP2
2.5M
LP+HP1 0.91
25K
3.52
10K
11.52
5K
FIXED
132
50Hz
TX Result
TX Result
RX Result
MIN p-p
MAX p-p
MIN p-p
OFF
OFF
N/A
OFF
OFF
N/A
0.15
0.25
0.116
0.15
0.25
0.111
0.82
1.00
0.776
3.30
3.74
3.174
10.90
12.14
10.401
124.37
139.63
113.40
RX Result
MAX p-p
0.070
0.070
0.284
0.291
1.044
3.866
12.426
150.60