NOTICE
Compatibility of units
When using variables (assignment, comparison, calculation, etc.) the compatibility of the
units involved is not checked. Should conversion be required, this is the sole responsibility of
the user/machine manufacturer.
See also
General information about variables General information about variables [Page 17]
1.1.10
Attribute: Access rights (APR, APW, APRP, APWP, APRB, APWB)
The following protection levels, which have to be specified during programming, correspond
to the access rights:
Access right
System password
Machine manufacturer password
Service password
End user password
Key-operated switch position 3
Key-operated switch position 2
Key-operated switch position 1
Key-operated switch position 0
Definition (DEF) of user variables
Access rights (APR.../APW...) can be defined for the following variables:
•
Global user data (GUD)
Job planning
Programming Manual, 02/2011, 6FC5398-2BP40-1BA0
Flexible NC programming
1.1 Variables
Protection level
0
1
2
3
4
5
6
7
41