Operation
62 ◆
Department Group access is available via Networking. When the extension at System A tries to
make a Department Call to System B, System A should have a numbering plan which deÞnes the
Department Access code at System-B (must be deÞned as dial type 8, Networking in Program 11-
01 : System Numbering).
The following Department Calling options are supported with the Networking feature.
Program Number
16-01-02
Department Calling Cycle
16-01-03
Department Routing When Busy
16-01-04
Hunting Mode
16-01-05
All Ring Mode
16-01-06
STG Withdraw Mode
16-01-07
Call Recall Restriction for STG
16-01-08
Maximum Queuing Number
16-01-10
Enhanced Hunting Mode
1.
When dialing the Department access code for the networked system, the call is dialed in the
the same way normal.
2.
A Department Call from the outgoing system will be routed to an available extension in the
Department Group.
Mode
When a call is transferred to a
Department Group with All Ring,
there is a difference in operation. In a
single system, an extension within
the same system can transfer a call to
a Department Group and the call will
ring an extension within the Depart-
ment Group once the transferring
user hangs up. In a networked sys-
tem, the transfer will not go through
and the call will recall the extension
performing the transfer.
Same as Single System
Yes
Yes
No
No
No
No
No
Networking