Document Revision 3
___________________________________________________________________________________
___________________________________________________________________________________
5 - 26
3.10.3
Fuse Replacement
For continued protection against risk of fire, replace
fuses with the same type and rating originally
installed.
1.
Turn off the power switch and remove the front cover on the
KSU. (Refer to
KSU.)
2.
Pull out the drawer that holds the PSU and disconnect the
cable as shown in
KSU.
Connections
3.
Replace the fuses as necessary and return the PSU to the
KSU. Fuse F1 is a 125V, 6A fuse for AC input. Fuse F101 is a
125V, 6.0A fuse for DC input.
Figure 5-4 Removing the Front Panel of the
Figure 5-25 Removing the PSU from the
Cable
Fuse
Figure 5-25 Removing the PSU from the KSU
Electra Elite IPK II
Installing KSUs