Clearing Rate Permanence Configuration Of A Specified Port (-C) - Huawei IN200 User Manual

Ethernet nic
Table of Contents

Advertisement

Huawei IN200 NIC
User Guide
Parameter
mode
Usage Instruction
l
l
l
l
Example
#Enable the GE mode for port 0.
[root@localhost ~]# hinicadm hilink_speed -i hinic0 -p 0 -m enable
Set default configuration succeed.
Active default configuration succeed.

6.1.4.23.5 Clearing Rate Permanence Configuration of a Specified Port (-c)

Function
The hilink_speed -c command is used to clear rate permanence configuration of a specified
port, namely, -d property in
s).
Format
hinicadm hilink_speed -i <devicename> -p <portid> -c
Parameters
Parameter
devicename
portid
Issue 06 (2019-07-27)
Description
Indicates the network port
connection mode.
If the command contains -d, the setting is permanent and takes effect after a restart.
If the command does not contain -d, the setting is not permanent and will be restored to
the factory setting after a restart.
The mode setting of port 0 correlates with port 1, and the setting of port 2 correlates with
port 3. For example, if mode is changed from enabled to disabled for port 0 and takes
effect, mode will be automatically changed to disabled for port 1.
Setting the GE mode takes effect after restart. After the GE mode is adopted, the FEC,
forced rate, and auto-negotiation cannot be configured.
Description
Indicates the name of the
IN200 to be configured in the
system.
Indicates the number of the
port to be set.
Copyright © Huawei Technologies Co., Ltd.
Value
l enabled: GE transmission is used.
l disabled: 10GE/25GE transmission is
6.1.4.23.2 Setting the Transmission Rate of a Specified Port (-
Value
Example: hinic0 or hinic1
-
6 Management Tools
used.