Axis Monitoring, Protection Zones (A3); Signals To Channel (Db21 - Siemens SINUMERIK 840Di Function Manual

Basic machine
Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Detailed Description

2.2 Axis monitoring, protection zones (A3)

2.2
Axis monitoring, protection zones (A3)
2.2
2.2.1

Signals to channel (DB21, ...)

DB21, ...
DBX1.1
Enable protection zones
Edge evaluation: yes
Signal state 1 or
When a positive edge of this signal appears, a protection zone is enabled and the active alarm
edge change
cleared. Then, motion can start in the same protection zone. As a result of the start of motion, the
0 → 1
protection zone is enabled, the IS "machine or channel-specific protection zone violated" is set, and
the axis starts to move.
The enabling signal is canceled if motion is started that does not lead into the enabled protection
zone.
Signal state 0 or
No effect
edge change
1 → 0
Application
This allows protection zones to be released:
example(s)
DB21, ...
DBX8.0 - DBX9.1
Activate machine-specific protection zone 1 ( ...10)
Edge evaluation: no
Signal state 1 or
The pre-activated, machine-related protection zone 1 ( ...10) is activated by the PLC user program.
edge change
The protection zone is immediately active.
0 → 1
Only protection zones that have been pre-activated in the part program can be activated.
Signal state 0 or
The pre-activated, machine-related protection zone 1 ( ...10) is de-activated by the PLC user
edge change
program.
1 → 0
The protection zone is immediately de-activated.
Only protection zones that have been activated via the PLC and have been pre-activated in the NC
part program can be deactivated.
Application
Before a sensor, for example, is moved into the working range, the relevant machine-related
example(s)
protection zone can be activated.
2-64
Signal(s) updated: cyclic
If the current position is within a protection zone (alarm 2 present)
If motion is to be started towards the protection zone limit
(alarm 1 or 2 present)
Signal(s) updated: cyclic
NC/PLC Interface Signals (Z1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0