Signals From Op (Db19) - Siemens SINUMERIK 840Di Function Manual

Basic machine
Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

DB19
DBX45.2
FC9 Out: Error
Edge evaluation: no
DB19
DBX45.3
FC9 Out: StartError
Edge evaluation: no
2.1.5

Signals from OP (DB19)

DB19
DBX20.1
Screen is dark
Edge evaluation: no
Signal state 1 or
The screen is darkened.
edge change 0 → 1
Signal state 0 or
The screen is not darkened.
edge change 1 → 0
Application
Using this IS, the PLC can identify whether the screen was switched dark using the interface
example(s)
signal:
DB19, DBX0.1 (darken screen)
or using the machine data:
MD9006 $MM_DISPLAY_BLACK_TIME (screen blanking time).
Corresponding to ....
MD9006 $MM_DISPLAY_BLACK_TIME (screen blanking time)
DB19
DBX20.3
Cancel alarm cleared
Edge evaluation: no
Signal state 1 or
Cancel alarm deleted active
edge change 0 → 1
Signal state 0 or
Cancel alarm deleted inactive
edge change 1 → 0
NC/PLC Interface Signals (Z1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
2.1 Various interface signals and functions (A2)
Detailed Description
2-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents