Item
Set the communication unit attached to the extension interface of the GOT.
GT21 and GS21 are not supported.
CH No.
Extend I/F Setting
Driver
Detail Setting
1.1.4

Precautions

■1. Precautions for changing model
(1) When devices that cannot be converted are included.
When setting of [Manufacturer] or [Controller Type] is changed, GT Designer3 displays the device that cannot be
converted (no corresponding device type, or excessive setting ranges) as [??]. In this case, set the device again.
(2) When the changed Manufacturer or Controller Type does not correspond to the network.
The network will be set to the host station.
(3) When the Manufacturer or Controller Type is changed to [None]
The GT Designer3 displays the device of the changed channel No. as [??]. In this case, set the device again.
Since the channel No. is retained, the objects can be reused in other channel No. in a batch by using the [Device
Bach Edit], [CH No. Batch Edit] or [Device List].
1 - 20
1.1 Setting the Communication Interface
Set the CH No. according to the intended purpose.
The number of channels differs depending on the GOT to be used.
0: Not used
1 to 4: Used for the controllers of channel numbers 1 to 4 set in controller setting (channel setting).
5 to 8: Used for the barcode function, the RFID function, and the remote personal computer operation
function (Serial).
A: Used for the video/RGB display function, multimedia function, external I/O function, operation panel
function, video output function, report function, hard copy function (with a printer), and sound output function.
Set the driver for the device to be connected.
• Each communication driver suitable to the channel numbers
• Each communication driver for connected devices
Set the detailed settings for the communication driver.
Refer to each chapter of the equipment to be connected to the GOT.
POINT
POINT
POINT
Channel No., drivers, [RS232 Setting]
(1) Channel No.2 to No.4
Use the channel No.2 to No.4 when using the Multi-channel function.
For details of the Multi-channel function, refer to the following.
GOT2000 Series Connection Manual (Mitsubishi Electric Products) For GT Works3
Version1
(2) Drivers
The displayed items for a driver differ according to the settings [Manufacturer], [Controller
Type] and [I/F].
When the driver to be set is not displayed, confirm if [Manufacturer], [Controller Type] and [I/
F] are correct.
[Setting the communication interface] section in each chapter
Description

Advertisement

Table of Contents
loading