Connecting To Z-Com - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal (non-mitsubishi electric products 2)
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

9.5.4

Connecting to Z-COM

■1. Communication settings
Item
*1
Communication speed
Communication protocol
Data bit
Parity
Stop bit
*2
Unit address
Interval time
Dip switch settings valid / invalid
*1
Adjust the settings with GOT settings.
*2
Select the unit address without overlapping with that of other units.
■2. Setting DIP switches
Make the settings of transmission speed, data bit configuration, communication protocol.
Setting item
Communication speed
(COM1)
Communication protocol
(COM1)
Communication speed
(COM2)
Communication protocol
(COM2)
Dip switch settings
valid / invalid
9600bps, 19200bps, 38400bps
Host (MODBUS)
8bits (fixed)
None (fixed)
1bit (fixed)
0 to F
0 to 250ms
valid
COM
COM.
PORT1
COM1
COM.
PORT2
COM.
PORT3
COM2
COM.
PORT4
Front side
Set value
1
9600bps
ON
19200bps
OFF
38400bps
ON
Host
(MODBUS)
9600bps
19200bps
Host
(MODBUS)
valid
Setting range
Dip switch
OFF ON
Right side
Switch position
2
3
4
OFF
ON
ON
ON
OFF
ON
ON
9.5 Temperature Controller Side Setting
5
6
7
8
OFF
OFF
OFF
9 - 57