Advanced Settings
Installer Access
To access the Installer Access, click Installer on the Advanced Settings screen and enter the Professional Access Code.
u
Enter any one of the Action Codes in parenthesis below to gain access to that specific setting:
u
Humidity Calibration (HC)
Ability to adjust humidity readings to improve sensor accuracy as the thermostat nears the end of its lifecycle after years of use.
Relative Humidity Hysteresis (HSD)
A humidity range between the current humidity and humidity set point, where the humidifier or dehumidifier is not engaged (also
called a deadband)
Initial Setup (IS)
Use this code to repeat the initial setup process.
Sensor Calibration (SC)
Ability to adjust temperature readings to improve sensor accuracy as the thermostat nears the end of its lifecycle after years of
use.
Sensitivity Level (SS)
Ability to adjust how sensitive your thermostat sensor is to changes in the air temperature. The lower the level, the more your
system cycles to maintain the setpoint.
Staging (ST)
Ability to adjust 3 configuration options for custom stage up and stage down control. Refer to next page
Unit Configuration (UC)
Use this code to repeat the unit configuration process.
18
Need
Screen
Latching
Stage Delay
Enables staging logic that will
Set the time delay between the
not cycle between stages
stage up logic for non-latching,
until the setpoint is met.
multi stage equipment.
Need
Need
Screen
Screen
Stage Temp
Set the temperature delay
between the stage up and stage
down logic for non-latching, multi
stage equipment.
19