Introduction - Bosch ACS 753 Repair Instructions

A/c service unit
Table of Contents

Advertisement

ACS 753, ACS 763, ACS 863 Service Manual
These units are designed to be compatible with existing service equipment and standard service
procedures. These machines utilize a single-pass system that meets specifications for recycled
refrigerant. Follow recommended service procedures for the containment of refrigerant.
Each unit includes a high-vacuum pump for fast, thorough evacuation. The compressor first pulls
the A/C system to -0.4 bar; the compressor then works with the vacuum pump to pull a vacuum
to an absolute pressure of less than 1.0 bar.
NOTE: Refrigerant systems require special oils. Refer to the A/C system manufacturer's service
manual for oil specifications.
14
13
12
11
10
9
1. Gauge low pressure (LP)
2. Visual alert
3. Gauge high pressure (HP)
4. 2 x USB 2.0 slot
5. Identifier Filter
(ACS 863 only)
6. Master switch
7. Circuit breaker
8. Power supply socket
9. UV dye bottle
10. Fresh oil bottle 2 (POE)
11. Fresh oil bottle 1 (PAG)
12. Used oil bottle
13. Printer
14. Display and control panel (HMI)
Robert Bosch GmbH

Introduction

1 2 3
Figure 1-1. Description of machine
23
4
5
6
7
8
15. N2H2 or N2 inlet port max 14 bar (1.4 MPa)
16. Flush port (high pressure*)
17. Flush port (low pressure*)
18. Service hose port (high pressure*)
19. Service hose port (low pressure*)
20. Contaminant recovery outlet port
(ACS 863 only)
21. Front wheels with locking brake
22. Rear wheels
23. Hoses wraping support
(*) max 25 bar (2.5 MPa)
9

Introduction

15
16
17
18
19
20
21
22
SP00D00609