Bosch ACS 753 Repair Instructions page 13

A/c service unit
Table of Contents

Advertisement

ACS 753, ACS 763, ACS 863 Service Manual
WiFi Configuration
To configure the WiFi connection to the ma-
chine. The display shows four selection options:
√ Search WiFi Networks: To search for
available WiFi networks.
√ WiFi status: To display some WiFi con-
nection data used.
√ Test WiFi connection: to perform a WiFi
network connection test used by the ma-
chine.
√ Disconnect current network: To disable
the WiFi network connection stored on the
machine.
Asanetwork
To enable or disable the asanetwork function.
For further information contact Customer Ser-
vice.
Connected Repair [CoRe]
To enable or disable the CoRe function.
For more information see Connected Repair
[CoRe] chapter on the user manual.
• Select BACK icon to return to the Setup
Menu.
Maintenance Menu
• Select Maintenance to access the follow-
ing functions.
Filter Maintenance
The filter removes acid, particulates, and mois-
ture from the refrigerant. To meet requirements,
it is mandatory to replace the filter after (SEE
TABLE) of refrigerant has been filtered.
Model
Replacement filter at: 68 kg
R134a
(alert 56 kg)
Model
Replacement filter at: 150 kg
R1234yf
(alert 138 kg)
This menu item displays the filter capacity re-
maining until the machine locks down and no
longer functions. Refer to Filter Maintenance in
the Maintenance section.
Robert Bosch GmbH
Pump Maintenance
Displays the amount of time remaining until
the next vacuum pump oil change is needed.
For maximum vacuum pump performance,
change vacuum pump oil every time the
filter is replaced. Refer to the Vacuum Pump
Maintenance in the Maintenance section.
ISV Purge Condition
Displays internal storage vessel (ISV) pressure
and temperature. It is used to eliminate
incondensables gas and helps to limit the
pressure in the ISV.
Calibration Check
Use to verify internal scale calibration. Refer to
Calibration Check in the Maintenance section
of this manual.
Adjust Zero Offset
To reset the fresh oil PAG, fresh oil POE, used
oil and UV dye scales.
Display Tittle Info
To activate or deactivate the pressure and
temperature values display of the machine.
System Information
Displays the revision level of the software in
the unit.
Service Menu
For service center use only.
Production Menu
For production use only.
• Select BACK icon to return to the Setup
Menu.
13
Introduction
SP00D00609
2018-03-26

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs 763Acs 863

Table of Contents