Readers
5.4 SIMATIC RF250R
5.4.5
Technical specifications of the RF250R reader
Product type designation
Inductive interface to the transponder
Transmission frequency for power/data
Connectable antennas
Interface
•
•
Baud rate
Cable length reader ↔ communications module
Transmit power
Read/write distances of reader
Maximum data transmission rate
reader ↔ transponder (tag)
•
•
Power supply
Display elements
Connection
•
•
Housing
•
•
•
Securing
Ambient temperature
•
•
Degree of protection to EN 60529
Shock to EN 60721-3-7 Class 7 M2
Vibration to EN 60721-3-7 Class 7 M2
Weight
96
Communications module
PC
Read
Write
Power supply/data line
Antenna
Dimensions (L × W × H)
Color
Material
During operation
During transportation and storage
RF250R
13.56 MHz
ANT 8, ANT 12, ANT 18, ANT 30
RS-422 (3964R protocol)
•
RS-232 (ASCII protocol)
•
19200, 57600, 115200 baud
RS-422: max. 1000 m
RS-232: Max. 30 m
(shielded cable)
180 mW (50 ohms)
Refer to chapter Field data (Page 35)
approx. 1.5 KBps
•
approx. 1.5 KBps
•
24 VDC
3-color LED
(operating voltage, presence, error)
M12, 8-pin, male
•
M8, 4-pin, female
•
50 × 50 × 30 mm (without M12 device
•
connector)
Anthracite
•
Plastic PA 6.6
•
2 x M5 screws
Tightening torque ≤ 1.5 Nm
-20 °C ... +70 °C
•
-25 °C ... +80 °C
•
IP67
50 g
20 g
Approx. 60 g
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6GT2821-5AC10
6GT2821-5AC40
SIMATIC RF200