Advertisement

Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
Read/write distance (S
)
g
Distance from metal
Multitag capability
Power supply
Degree of protection according to EN 60529
Vibration-resistant to EN 60721-3-7, Class 7M3
Torsion and bending load
Housing
Dimensions (L x W x H)
Color
Material
Securing
Ambient temperature
Weight
The values for vibration are maximum values and must not be applied continuously.
1)
7.13.5

Dimension drawing

Figure 7-33
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
During operation
During transportation and
storage
Dimensional drawing MDS D400 (dimensions in mm)
10 years
≥ 2 x 10
hours
6
> 10
10
> 10
10
See section "Field data (Page 35)"
≥ 20 mm
Yes
inductive power transmission (without battery)
IP67
ISO 10373 / ISO 7810
1)
ISO 10373/ISO 7816-1
Laminated plastic card, printable
85.6 (±0.3) × 54 (±0.2) × 0.8 (±0.05) mm
White
PVC
Adhesive, fixing lug
-25 ... +60 ℃
-25 ... +60 ℃
Approx. 5 g
Transponder
7.13 MDS D400