Transponder
7.1 MDS D100
7.1.4
Technical data
Table 7- 3
Memory size
Memory configuration
•
•
•
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles, typical
Write cycles, min.
Read/write distance (S
Distance from metal
Multitag capability
Power supply
Degree of protection to EN 60529
Vibration
Torsion and bending load
Mechanical design
•
•
•
Fixing
Ambient temperature
•
•
Weight, approx.
158
Technical data for MDS D100
Serial number
Configuration memory
Application memory
)
g
Color
Material
Dimensions (L x W x H) in mm
During operation
Transport and storage
128 bytes
8 bytes (fixed code)
•
8 bytes
•
112 bytes
•
EEPROM
EEPROM 128 bytes gross
112 bytes net capacity
When using the OPT area, 16 bytes of it must be
subtracted in 4 byte blocks
according to ISO 15693
10 years
2 x 10
hours
6
Unlimited
1 000 000
100 000
See Chapter Field data (Page 35).
min. 20 mm (approx. 30% reduction of the field data)
Yes
Inductive power transmission (without battery)
IP68
ISO 10373/ISO 7810
ISO 10373/ISO 7816-1
Laminated plastic card, printable on both sides
White/petrol
•
PC
•
85.6 (±0.2) x 54 (±0.2) x 0.9 (±0.05)
•
Adhesive, fixing pocket
-25 °C to +80 °C
•
-25 °C to +80 °C
•
5 g
System Manual, 09/2013, J31069-D0227-U001-A8-7618