GE CRxVision Operating Manual page 30

Computed radiography
Table of Contents

Advertisement

Linearization can be applied to the scanned image by selecting the Linearize Data setting.
Connectivity status with the digitizer is available through selection of the View Connection
Status option. It will provide a detailed accounting of the transmission of messages between
the digitizer and the Rhythm acquisition software. This information is also logged to a file and
can be used to diagnose issues with connectivity.
On receipt of image data from a scanned plate, the Rhythm acquisition software will check
the integrity of the data and will then present a dialog that can be used to tag editable
DICONDE fields and also crop the image into smaller images of interest.
The image will be displayed in the viewport. If the plate detection option was selected in the
digitizer interface discussed above, there may be ROI's which are positioned in the image
correlating to the edges of any plates that are present in a parallel scan scenario.
Further, the ROI's will be listed in the list to the left. If more cropping areas are desired,
please select the Add button and an ROI will be added to the viewport that can be moved
and sized as necessary. ROI's that are not correctly placed can also be removed from the
image by selecting the Delete button.
DICONDE tag management is done on a per ROI basis, unless there are no ROI's
positioned in which case they are just applied to the full image. The component name,
component id and study id DICONDE tags will not be editable in Rhythm RT as those fields
are pre-populated by the technique database. For Rhythm RT Lite these fields are fully
editable. The Series description and image comments are editable per ROI.
The Rhythm RT Lite also allows for the naming of the final name to be populated in the
image list. On completion of ROI adjustment and DICONDE mapping, save images to the
Rhythm acquisition system by selecting Save All Images. You can close the dialog by
selecting the Close option when complete. Be ware that the digitizer acquisition will be
cleared on close of the dialog.
After successful scan, images can be sent over to Rhythm Review for post processing.
30
CRxVision Operating Manual V1.2