Ci = 4 nF
Li = 10 uH
7.5 SVi1000 (+) and (-) Position Retransmit (4-20mA Output) Terminals
These terminal provide the 4-20mA position retransmit output and are equipped only on the
Position Retransmit Terminal board. A transmitter type barrier with 250 Ohm series resistance
(internal or external) could be used for this connection.
Entity Parameters:
Vmax= 30 Vdc
Imax=125 mA
Pmax = 900 mW
Ci = 8 nF
Li = 1 uH
7.6 Entity Requirement
Cable capacitance and inductance plus the I.S. apparatus unprotected capacitance (Ci) and
inductance (Li) must not exceed the allowed capacitance (Ca) and inductance (La) indicated
on the associated apparatus. If the optional Hand Held Communicator is used on the
Hazardous Area side of the barrier, then the capacity and inductance of the communicator
must be added and the communicator must be agency approved for use in the hazardous
area. Also, the current output of the Hand Held Communicator must be included in the
current output of the associated equipment.
The barriers may be active or passive and from any certified manufacturer as long as the
barriers comply with the listed entity parameters.
7.7 Installation Restriction
A device which has previously been installed without an approved IS barrier must NEVER be
used subsequently in an intrinsically safe system. Installing the device without a barrier can
permanently damage the safety related components in the device making the device
unsuitable for use in an intrinsically system.
Repair
8
WARNING: EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY
FOR USE IN A HAZARDOUS LOCATION.
Only qualified service personnel are permitted to make repairs on the SVi1000 positioner.
Replace ONLY with genuine GE parts.
Replacement of the Main electronics board, Basic, Switch and Position Retransmit Terminal
boards, Housing cover kit, pressure gauges, I/P assembly and Integral magnet assembly are
the only field repairs permitted.
Copyright 2015 as an unpublished trade secret. This document and all information herein is the property of Dresser Flow
Technologies, Dresser Inc. It is confidential and must not be made public or copied and is subject to return upon demand.
© 2016 General Electric Company. All rights reserved
ES-761 Rev F
.