Cabinet Mounting
– continued
4
Figure 4-2: Cabinet Mounting Brackets
70
Step
4
5
SC
4812ET RF and Power Cabinet Hardware Installation Manual
TM
Table 4-2: Concrete Pad Mounting
Remove the four (4) eye–bolts (see Figure 4-2) on the top of
the cabinet, replace them with the bolts and washers supplied
with the installation hardware using a 24 mm (15/16") hex
driver. Torque to 80 N–m (60 ft–lbs).
Install the wiring as described in Chapter 5 of this manual.
NOTE
The isolation washers supplied in the hardware installation
kit are provided to give the installer the option of
electrically isolating the cabinet should the situation
require it. The use of the washers is not a requirement.
The grounding of each site is unique, and the isolation of
the cabinet is a site specific decision.