Site Preparation
2
Heliax
Heliax
Cable
RG 142
CGDSRG142BU
3/8" LDF
N/A
1/2"LDF
SGDN4232A
1/2" FSJ4
N/A
7/8"LDF
SGDN4234A
1–1/4"LDF
SGDN4235A
1–5/8"LDF
SGDN4233A
NOTE
As an additional rule of thumb, allow 0.1 dB additional loss for each connection point.
Conduit
Conduit
Trade Size
9.5 mm (3/8")
2"
2–1/2"
3"
4"
6"
* IMPORTANT
The values listed above were calculated based on the percent of conduit cross–section filled and recommended
limits set forth by Andrew Corporation. These limits are based on common conditions or proper cabling and
alignment of conductors where the length of pull and the number of bends are within reasonable limits. It
should be recognized that for certain conditions a larger size conduit or a lessor fill should be considered.
44
– continued
Table 2-6: Heliax Cable Loss and Minimum Bend Radii
dB loss per meter
Motorola Part
Motorola Part
No.
@ 1 GHz
.49
.115
.0768
.119
.0430
.0317
.0269
Table 2-7: Number of wires in Conduit
Foam Heliax Trade Size (Cable Type LDF)
12.7 mm (1/2")
5
2
7
3
11
5
19
9
20
20
Power Cabinet AC Power Connection
208–240 VAC – Flexible Liquid Tight Conduit is recommended.
SC
4812ET RF and Power Cabinet Hardware Installation Manual
TM
NOTE
It may not be necessary or desirable to run the transmission
lines in any conduit at all. In this case the transmission
lines should be protected from falling objects (i.e., ice,
etc.) or from being stepped on.
dB loss per foot
@ 2 GHz
@ 1 GHz
.66
.15
.167
.035
.1132
.0234
.177
.0363
.0646
.0131
.0476
.00967
.0410
.00819
21.4 mm (7/8")
31.8 mm (1–1/4")
1
1
3
5
12
Min. bend radius
@ 2 GHz
Metric
.20
10 mm
.051
95 mm
.0345
125 mm
.0541
13.75 mm
.0197
250 mm
.0145
380 mm
.0125
510 mm
41.3 mm (1–5/8")
1
3
DRAFT
U.S.
.4"
3–3/4"
5"
1.25"
10"
15"
20"
1
2
Apr 2001