Mhz To 2.5 Ghz Sensitivity For Hp 53131A/132A Option 030 Only - HP 53132A Assembly And Service Manual

225 mhz counter
Hide thumbs Also See for 53132A:
Table of Contents

Advertisement

1
HP 53131A/132A
Counter
Channel 3
Figure 1-9. Option 030/050/124 Channel 3 Frequency Sensitivity and Accuracy Test Setup
2
Chapter 1 Performance Tests
Test 5: Option 030/050/124 Channel 3 Frequency Sensitivity (HP
53131A/132A Only)
100 MHz to 2.5 GHz Sensitivity for HP 53131A/132A
Option 030 only
Set the HP 8663B Synthesized Signal Generator to output a
2500 MHz, −40 dBm sine wave, and connect the signal to Channel 3
of the Counter as shown in Figure 1-9.
50Ω
Feedthrough
Ref. In
(rear panel)
On the Counter, Press Run key.
Assembly-Level Service Guide
HP 8340B
Sweep Oscillator
HP 8663A
Synthesized Signal Generator
Frequency Standard
(switch set to EXT)
Output
Input
(rear panel)
Output
N-to-BNC
Connector
1-31