1.1 Names and Mechanisms of Units
2. Rear view
1
4Z4C-AB01
No.
Unit name
Status indicator
(Three-color signal tower)
Regulator knob
(Inside the cover)
Stage indicator lamp
EJM4A-019P
Explanation of status indicator lamp (three-color signal tower)
EJM4A-122E
Page 1-4
3
Indicates the machine's operational
status, and warns you of any trouble
occurred during operation by sounding
a buzzer. You can adjust the volume of
buzzer using the knob.
Used to adjust the supply air pressure.
If components run out or trouble occurs,
the corresponding stage lamp blinks.
During automatic operation
• Not lit: Normally running
• Lit: Components have run out.
• Blinking: Warning of the shortage of
component
During teaching
• Lit: Running
Color,
Status
Red,
Trouble; operation cannot be
Blinking
continued. (Emergency stop)
Yellow,
Trouble or warning; operation can
Blinking
be continued.
During automatic operation, or
Green, Lit
during machine adjustment
running
Knob
CM602-L
Reference Manual
3
EJM4A-062P
Function
Description
2
Qty.
Reference item
1
See below.
1
Operation Manual
4
Trouble description
• Emergency stop
• Trouble in shafts of motors, etc.
• Drop in air pressure
• Board transport trouble
Immediate/Cycle stop, Out of materials
Normally running
EJM4A-E-RMA01-A01-00