1.4 Other Specifications
<Vacuum sensor setting procedure>
Setting procedures of vacuum sensor (Example: For CM20/CM120/CM100)
Make the setting on each head. (Three indicators need to be set.)
Page 1-28
CM602-L
Reference Manual
1.
Select the channels to be set, using
and
2.
Change the pressure value using
and
pressing
• This step covers the setting of pressure value
(H −
Indication example:
∗ For setting values, refer to the specifications
(the setting values of vacuum sensor below).
3.
Change the pressure value using
and
pressing
• This step covers the setting of pressure value
(h −
Indication example:
∗ For setting values, refer to the specifications
(the setting values of vacuum sensor below).
[Setting values of vacuum sensor]
H − 1 = P0 + 1.0
h − 1 = − 1.0
H − 2 = − 10 (Original setting value: − 20)
h − 2 = 0
H − 3 = P0 + 1.0
h − 3 = − 1.0
H − 4 = − 10 (Original setting value: − 20)
h − 4 = 0
P0: Vacuum pressure of 1003 nozzle
1.
Change the settings of pressure values.
Setting value P3 (Original setting value:
− 149 ) ⇒ − 74
Setting value P4 (Original setting value:
− 150 ) ⇒ − 75
(How to check)
Pressing
(P − 1, ... P − 5), alternating with the setting value.
(How to change the settings)
Change the setting values, using
keys.
keys.
keys, and accept your entry by
.
).
H − 1
Alternately
keys, and accept your entry by
.
).
h − 1
Alternately
toggles an indication in order
EJM4A-E-RMA01-A01-00
− 46.0
− 1.0
and