Machine Specifications; Equipment Specifications - Panasonic CM602-L Reference Manual

Table of Contents

Advertisement

1.3 Equipment Specifications

1.3 Equipment Specifications

1.3.1 Machine Specifications

Item
Control system
Microcomputer system
The data is managed by PT
External memory
Approximately 1 MB is required for a piece of data. (One type per 3.5-inch 2HD floppy disk)
∗ 1
Program data
Point count: Max. 10000 points
Machine body
Power source
Power supply for
HUB
Machine body
Rated capacity
Power supply for
HUB
Supply air pressure
0.49 MPa to 0.78 MPa (Working air pressure: 0.49 MPa to 0.54 MPa)
Supply air volume
170 L/min (A.N.R.)
2350 mm (W) × 2690 mm (D) × 1430 mm (H)
Outside dimension
(Three-color signal tower and color touch panels not included)
Mass of main body
Mass of collectively
∗ 2
Mass
changing truck
Mass of standard
configuration
Temperature: 10 ° C to 35 ° C
Environmental
condition
Humidity: 25% RH to 75% RH (No condensation)
Temperature: − 20 ° C to 60 ° C
Transportation and
storage condition
Humidity: 75% RH or less (No condensation)
Altitude
1000 m or less, above sea level
Noise
< 70 dB (A)
∗ 1 : The data is created by PT. This machine can modify only some data.
∗ 2 : Mass of the main body excluding the optional units
∗ 3 : The power supply for HUB is an option. This power supply is required when you wish to
communicate with PT while the main power supply is OFF.
∗ 4 : PT (Programming Terminal Support System), which creates and manages the production data.
Page 1-12
CM602-L
Reference Manual
∗ 4
Normal service source: Three-phase 200/220 VAC ± 10 VAC,
Frequency: 50/60 Hz
Single-phase 100 VAC to 240 VAC, Frequency: 50/60 Hz
∗ 3
4.0 kVA
140 VA
∗ 3
3400 kg (Standard configuration, excluding 140 kg of a collectively
changing truck)
140 kg (per unit)
3960 kg (One main body and four collectively changing trucks)
Specifications
.
Three-phase 380/400/420/480 VAC ± 20 VAC
EJM4A-E-RMA01-A01-00