336 Parameters
No.
Name/Value
Ambient
temperature
Other
36.07
AL2 signal scaling
0.00 ... 32767.00
36.09
Reset loggers
Done
All
PVL
AL2
36.10
PVL peak value
-32768.00 ...
32767.00
36.11
PVL peak date
-
36.12
PVL peak time
-
36.13
PVL current at peak
-32768.00 ...
32767.00 A
36.14
PVL DC voltage at
peak
0.00 ... 2000.00 V
36.15
PVL speed at peak
-32768.00 ...
32767.00 rpm
36.16
PVL reset date
-
36.17
PVL reset time
-
36.20
AL1 below 10%
0.00 ... 100.00%
36.21
AL1 10 to 20%
0.00 ... 100.00%
36.22
AL1 20 to 30%
0.00 ... 100.00%
Description
01.70 Ambient temperature %
The amplitude range of 0...100% corresponds to 0...60 °C or
32...140 °F.
Source selection (see
Terms and abbreviations
Defines the signal value that corresponds to 100% amplitude. 100.00
Signal value corresponding to 100%.
Resets the peak value logger and/or amplitude logger 2.
(Amplitude logger 1 cannot be reset.)
Reset completed or not requested (normal operation).
Reset both the peak value logger and amplitude logger 2.
Reset the peak value logger.
Reset amplitude logger 2.
Displays the peak value recorded by the peak value logger.
Peak value.
Displays the date on which the peak value was recorded.
Peak occurrence date.
Displays the time at which the peak value was recorded.
Peak occurrence time.
Displays the motor current at the moment the peak value was
recorded.
Motor current at peak.
Displays the voltage in the intermediate DC circuit of the drive
at the moment the peak value was recorded.
DC voltage at peak.
Displays the motor speed at the moment the peak value was
recorded.
Motor speed at peak.
Displays the date on which the peak value logger was last
reset.
Last reset date of the peak value logger.
Displays the time at which the peak value logger was last
reset.
Last reset time of the peak value logger.
Displays the percentage of samples recorded by amplitude
logger 1 that fall between 0 and 10%.
Amplitude logger 1 samples between 0 and 10%.
Displays the percentage of samples recorded by amplitude
logger 1 that fall between 10 and 20%.
Amplitude logger 1 samples between 10 and 20%.
Displays the percentage of samples recorded by amplitude
logger 1 that fall between 20 and 30%.
Amplitude logger 1 samples between 20 and 30%.
(page 155).
on page 148). -
Def/FbEq16
20
1 = 1
Done
0
1
2
3
0.00
1 = 1
-
-
-
-
0.00 A
1 = 1 A
0.00 V
10 = 1 V
0.00 rpm
See par.
46.01
-
-
-
-
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%