Xhub Controller Specifications; Rx Splitter Specifications; Table 125: Xhub Controller Specifications; Table 126: Mts 4 Expansion Cabinet Rx Splitter Specifications - Motorola DIMETRA MTS 4 Installation, Configuration, And Service Manual

Dimetra ip scalable (dips); dimetra ip compact (dipc)/scalable dimetra ip (sdip); dimetra ip micro/dimetra ip lite
Table of Contents

Advertisement

Applicant: Motorola Solutions
370 | Technical Specifications
PSU Specifications
Safety
EMC
Dimensions
Weight

XHUB Controller Specifications

The following table lists the XHUB controller performance specifications.

Table 125: XHUB Controller Specifications

XHUB Controller Specification
Power Consumption
Dimension
Weight

RX Splitter Specifications

The following table lists the RX Splitter specifications.

Table 126: MTS 4 Expansion Cabinet RX Splitter Specifications

RX Splitter Specification
Dimension
Weight
Send Feedback
| September 2014 | 6802800U74-AD
Description
Hold up time, at 48 VDC input dropout: 2 ms @ 48 VDC operation, full load
and +30 °C
Minimum current when power supply switch is turned off: 2 mA
EN 60950-1/2001, UL 1950, CSA 22.2 No. 950, protection class 1, DC out-
puts designed as Safety Extra Low Voltage CE marked, designed to meet CB
certification and cULus requirements
Immunity: EN 55024/1998 + A1/2001 EN 61000-4-3, EN 61000-4-2, EN
61000-4-6, EN 61000-4-5, EN 61000-4-4, EN 61000-4-11
Emission: EN 55022 class A EN 61000-3-3, EN 61000-3-2
Height: 240 mm
Width: 97 mm
Depth: 391 mm
5 kg
Value or Range
5 W to 8 W
Height: 240 mm
Width: 61 mm
Depth: 393 mm
2.2 kg
Value or Range
Height: 139 mm
Width: 124 mm
Depth: 45 mm
0.4 kg
Equipment Type: ABZ89FC5827 / 109AB-5827