password: Specifies the password string. This argument is case sensitive. If you specify the simple
keyword, the password must be a string of 1 to 32 characters. If you specify the cipher keyword, the
password must be a string of 1 to 73 characters.
Usage guidelines
For security purposes, all passwords, including passwords configured in plain text, are saved in cipher
text.
Examples
# Set the FTP login password to ftpuser.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type ftp
[Sysname-nqa-admin-test-ftp] password simple ftpuser
Related commands
operation
username

probe count

Use probe count to specify the probe times.
Use undo probe count to restore the default.
Syntax
probe count times
undo probe count
Default
In an UDP tracert operation, the NQA client performs three probes to each hop along the path.
In other types of operations, the NQA client performs one probe to the destination per operation.
Views
DHCP/DLSw/DNS/FTP/HTTP/SNMP/TCP operation view
ICMP/UDP echo operation view
UDP jitter operation view
UDP tracert operation view
Predefined user roles
network-admin
Parameters
times: Specifies the probe times.
For the UDP tracert operation, this argument specifies the times of probes to each hop along the
path. The value range for this argument is 1 to 10.
For other types of operations, this argument specifies the times of probes to the destination per
operation. The value range for this argument is 1 to 15.