Husqvarna DXR250 Operator's Manual page 69

Demolition robots
Hide thumbs Also See for DXR250:
Table of Contents

Advertisement

Cable/Sensor error
Message on the
display
Cable to * has faulty
circuit. Please check
cable.
Cable to * has feedback
current without control
current. Please check
cable.
All warnings associated
with ** are disabled. Use
machine with caution
*Cable error
Cylinder 1, valve
Cylinder 2, valve
Cylinder 3, valve
Cylinder 4, valve
Cylinder 5, valve
Outrigger proportional, valve
Left caterpillar track, valve
Right caterpillar track, valve
Rotation, valve
Tool, valve
Extra function 1, valve
Extra function 2, valve
Front left outrigger, valve
Front right outrigger, valve
Rear left outrigger, valve
Rear right outrigger, valve
Rear dozer blade, valve
Front dozer blade, valve
Pressure, valve
**Sensor error
Temperature sensor
Pressure sensor
TROUBLESHOOTING
Indication on the
Effect on machine
machine
functions
No indication on
The function using
machine.
the cable disabled.
All supervision using
the sensor is
disabled.
(DXR270, DXR300, DXR310)
(DXR270, DXR300, DXR310)
(DXR270, DXR300, DXR310)
(DXR270, DXR300, DXR310)
(DXR250)
(DXR250)
Cause
Possible action
The cable has a
short circuit or
broken circuit.
Check cable.
The cable * have
feedback current
without being active.
Check the sensor *
Sensor ** is faulty.
and cables to the
sensor.
English – 69