HP 10500 Series Configuration Manual page 129

Layer 3 - ip services
Hide thumbs Also See for 10500 Series:
Table of Contents

Advertisement

Parameters
M flag
O flag
Router Lifetime
Retrans Timer
Reachable Time
To allow sending of RA messages:
Step
1.
Enter system view.
2.
Enter interface view.
Disable RA message
3.
suppression.
4.
Configure the maximum and
minimum intervals for
sending RA messages.
To configure parameters related to RA messages:
Step
1.
Enter system view.
2.
Configure the hop limit.
Description
Determines whether hosts use the stateful autoconfiguration to acquire IPv6
addresses.
If the M flag is set to 1, hosts use the stateful autoconfiguration (for example, through
a DHCP server) to acquire IPv6 addresses. Otherwise, hosts use the stateless
autoconfiguration to acquire IPv6 addresses and generate IPv6 addresses
according to their own link-layer addresses and the obtained prefix information.
Determines whether hosts use stateful autoconfiguration to acquire other
configuration information.
If the O flag is set to 1, hosts use stateful autoconfiguration (for example, through a
DHCP server) to acquire other configuration information. Otherwise, hosts use
stateless autoconfiguration to acquire other configuration information.
This field tells the receiving hosts how long the advertising device can live.
If the device fails to receive a response message within the specified time after
sending an NS message, it retransmits the NS message.
If the neighbor reachability detection shows that a neighbor is reachable, the
device considers the neighbor reachable within the specified reachable time. If the
device must send a packet to the neighbor after the specified reachable time
expires, the device reconfirms whether the neighbor is reachable.
Command
system-view
interface interface-type
interface-number
undo ipv6 nd ra halt
ipv6 nd ra interval
max-interval-value
min-interval-value
Command
system-view
ipv6 nd hop-limit value
120
Remarks
N/A
N/A
By default, RA messages are suppressed.
Optional.
By default, the maximum interval for
sending RA messages is 600 seconds,
and the minimum interval is 200
seconds.
The device sends RA messages at
random intervals between the maximum
interval and the minimum interval.
The minimum interval should be less than
or equal to 0.75 times the maximum
interval.
Remarks
N/A
Optional.
64 by default.

Advertisement

Table of Contents
loading

Table of Contents