Event Interface - HP FlexFabric 12500 Series Network Management And Monitoring Command Reference

Routing
Hide thumbs Also See for FlexFabric 12500 Series:
Table of Contents

Advertisement

Examples
# (In standalone mode.) Configure a CLI-defined policy to monitor the card in slot 2 for card swapping.
<Sysname> system-view
[Sysname] rtm cli-policy test
[Sysname-rtm-test] event hotplug slot 2
# (In IRF mode.) Configure a CLI-defined policy to monitor the card in slot 2 of IRF member device 1 for
card swapping.
<Sysname> system-view
[Sysname] rtm cli-policy test
[Sysname-rtm-test] event hotplug chassis 1 slot 2

event interface

Use event interface to configure an interface event for a CLI-defined monitor policy.
Use undo event to delete the event in a CLI-defined monitor policy.
Syntax
event interface interface-type interface-number monitor-obj monitor-obj start-op start-op start-val
start-val restart-op restart-op restart-val restart-val [ interval interval ]
undo event
Default
No interface events are configured.
Views
CLI-defined policy view
Predefined user roles
network-admin
mdc-admin
Parameters
interface-type interface-number: Specifies an interface by its type and number.
monitor-obj monitor-obj: Specifies the traffic statistic to be monitored on the interface. For keywords
available for the monitor-obj argument, see
start-op start-op: Specifies the operator for comparing the monitored traffic statistic with the start
threshold. The policy is triggered if the comparison result meets the condition. For keywords available for
the start-op argument, see
start-val start-val: Specifies the start threshold to be compared with the monitored traffic statistic. The
value range is 0 to 4294967295.
restart-op restart-op: Specifies the operator for comparing the monitored traffic statistic with the restart
threshold. The policy is executed if the comparison result meets the condition. For keywords available for
the restart-op argument, see
restart-val restart-val: Specifies the restart threshold to be compared with the monitored traffic statistic.
The value range is 0 to 4294967295.
Table
Table
52.
Table
52.
244
51.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flexfabric 12500e series

Table of Contents