Plc Side Setting - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

10.2.6

PLC Side Setting

■1. Directly connecting to the CPU
Item
*1
Baud Rate
Parity
Control Line
Communication Driver
Duplicate Packet
Detection
Station Address
Error Detection
*1
*2
■2. Connecting to DH485 network via adapter (1770-KF3)
(1) Setting of the adapter side
Item
*1
RS232 Baud Rate
Parity
Flow Control
DF1 Device
Category
*2
Error Detection
*5
DH-485 Baud Rate
Maximum Node Address
DH-485 Node Address
*1
*2
*3
*4
*5
10 - 16
10.2 Serial Connection
POINT
POINT
POINT
ALLEN-BRADLEY PLC
For details of ALLEN-BRADLEY PLCs, refer to the following manuals.
ALLEN-BRADLEY PLC user's Manual
4800bps,
9600bps,
19200bps
Set the Baud Rate according to the transmission speed setting on the GOT side.
For the transmission speed setting on the GOT side, refer to the following.
10.2.5 ■2. Communication detail settings
Set the Error Detection according to the sum check format setting on the GOT side.
For the sum check format setting on the GOT side, refer to the following.
10.2.5 ■2. Communication detail settings
Set the RS232 Baud Rate according to the transmission speed setting on the GOT side.
For the transmission speed setting on the GOT side, refer to the following.
10.2.5 ■2. Communication detail settings
Set the Error Detection according to the sum check format setting on the GOT side.
For the sum check format setting on the GOT side, refer to the following.
10.2.5 ■2. Communication detail settings
For the Maximum Node Address, set the same address as the Maximum Node Address on the DH-485 network.
Set the DH-485 Node Address according to the Host Address on the GOT side.
Set a unique DH-485 Node Address so that it does not conflict with the Node Address of the PLC CPU on the DH-485 network.
For the Host Address setting on the GOT side, refer to the following.
10.2.5 ■2. Communication detail settings
Set the DH-485 baud rate according to the baud rate on the CPU side.
SLC500
Series
EVEN
NO HANDSHAKING
DF1 HALF-DUPLEX SLAVE
BCC
4800bps, 9600bps, 19200bps
SLC500 series: EVEN, MicroLogix series: NONE
Disable (No Handshaking)
DF1 half-duplex slave, local mode
SLC500 series: BCC, MicroLogix series: BCC/CRC
9600bps, 19200bps
Setting details
MicroLogix
1000/1200/
1500 Series
4800bps,
9600bps,
19200bps,
38400bps
NONE
DISABLE
0
*2
BCC, CRC
Setting details
*3
1 to 31
*4
0 to 31
Control/
Compact/
FlexLogix
Series
4800bps,
9600bps,
19200bps,
38400bps
NONE
*2
BCC, CRC