Toshiba e-STUDIO2020C Service Handbook page 245

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO2020C:
Table of Contents

Advertisement

[C] Confirmation of the error
"Back Up ERROR X" (X: Error number) is displayed at the top of the LCD screen when the data have
not been properly backed up / restored. In this case, turn the power OFF and then check the following
items. After confirming and solving the problem, back up / restore the data again from the beginning.
Does the USB media meet the conditions being used for this cloning?
Is the updated program file written on the USB media properly?
Is the USB media installed properly?
Is the USB media or the equipment damaged?
Error number
ERROR 1
ERROR 2
ERROR 3
ERROR 4
ERROR 5
ERROR 6
ERROR 7
ERROR 8
ERROR 9
ERROR 10
ERROR 11
ERROR 12
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-12
Error content
Copy error
I/F error
USB memory full error
Working folder error
File not found error
Security error
Checksum error
Model check error
Version check error
Destination check error
Serial number check error
Device is Busy
e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C
4 - 13
BACKUP FUNCTION