12.95
The DMP compact module 1I analog is used for input and digitizing of an ana-
log voltage value. This voltage value is measured by a floating differential input.
Resistance thermometers PT100 can be connected in conjunction with the
built-in stabilized voltage source (2.5mA).
Table 8-5
Digital representation of analog values for DMP compact module 1 I analog
Input word
7
6
11
VZ 2
5
Significance
0
1
0
1
0
1
0
0
Digital value
0
0
0
0
1
1
1
1
1
1
1
0
1
0
0 = Always 0
OR= Overflow bit, input voltage exceeds 20V or 1V (double the input range)
PF = Failure of power supply to analog part.
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
8.4 DMP compact module 1I analog (6FC5 111-0CA04-0AA0)
IB m
IB m+1
5
4
3
2
1
0
7
6
10
9
8
7
6
4
3
2
2
2
2
2
2
2
2
0
1
1
1
1
1
1
1
1
:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
:
0
0
0
0
0
0
0
0
8 DMP Compact Modules
Analog input voltage
5
4
3
2
1
0
10V range
2
1
2
2
2
0
0R
PF
1
1
1
0
0
0
19.995V
:
:
0
0
1
0
0
0
10.005V
0
0
0
0
0
0
10V
1
1
1
0
0
0
9.995V
:
:
0
0
1
0
0
0
0.005V
0
0
0
0
0
0
0V
1
1
1
0
0
0
- -0.005V
:
:
0
0
1
0
0
0
- -9.995V
0
0
0
0
0
0
- -10V
1
1
1
0
0
0
- -10.005V
:
:
0
0
1
0
0
0
- - 19.995V
500mV range
999.76mV
:
500.24mV
500mV
499.76mV
:
0.24mV
0mV
- -0.24mV
:
- -499.76mV
- -500mV
- -500.24mV
:
- - 999.76mV