Connectable Drive-Cliq Components - Siemens SINUMERIK 840D sl Manual

Sinumerik 840d sl type 1b ncu 7x0.3 pn, ncu 7x0.3b pn
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Connecting
7.5 DRIVE-CLiQ components
Characteristic
Max. cable length
7.5.2

Connectable DRIVE-CLiQ components

Components
As a rule, all SINAMICS/SIMOTION components approved for SINUMERIK can be connected
to an NCU using DRIVE-CLiQ.
Table 7-8
Component
NX10.3 / 15.3
SINAMICS S120, system components, booksize format
Smart / Active / Basic
Line Module
Single / Double Motor Module Motor Modules draw their power from the DC link to supply the
HF Motor Module
SINAMICS S120, system components, chassis format
Smart / Active / Basic Line
Module
Motor Module
Power Module
CUA31
SINAMICS S120 Combi (only in connection with NCU 710.3)
Power Module
Motor Module Booksize
Compact
SINAMICS S120, additional system components
SMC10/20/30
SME20 / 25
SME120 / 125
DMC20/DME20
TM15 / TM17
54
Version
MOTION CONNECT (outside the control cabinet)
70 m
Components with DRIVE-CLiQ
Description
Drive expansion module for up to 6 axes
Line Modules provide the central power supply to the DC link.
connected motors.
Operates as inverter and provides the energy for the
connected motor - High Frequency Drive.
Line Modules provide the central power supply to the DC link.
Motor Modules draw their power from the DC link to supply the
connected motors.
Power Modules provide the energy for the connected motor.
Adapter to connect a Power Module to the NCU.
Integrated infeed, Motor Modules for 3 or 4 axs and TTL encoder
evaluation for the spindle.
Expansion axes for Power Modules.
Cabinet-Mounted Sensor Modules are needed when a motor with a
DRIVE-CLiQ interface is not available and when external encoders are
required in addition to the motor encoder.
Measuring systems outside the cabinet can be connected directly to the
Sensor Module External.
DRIVE-CLiQ Hub Modules are used to implement star-shaped
distribution of a DRIVE-CLiQ line.
The number of available digital inputs and outputs within a drive system
can be expanded using a Terminal Module.
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents