9.3.5.4

Examples

The following examples for assigning parameters to analog inputs / outputs are provided for
the I/O module with device number "7".
Table 9-62
Measured values and responses in the voltage measurement operating mode
Address
Operating mode
QB72
Format
QB73
Value
QW76
Value
QW78
Operating mode
IB72
Format
IB73
Value
IW76
Value
IW78
Diagnostics
IB50
IB51
PNFault LED
Troubleshooting
Table 9-63
Measured values and responses in the current measurement operating mode
Address
Operating mode
QB72
Format
QB73
Value
QW76
Value
QW78
Operating mode
IB72
Format
IB73
Value
IW76
Value
IW78
Diagnostics
IB50
IB51
PNFault LED
Troubleshooting
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
0 V
2.5 V
16#55
16#55
16#1
16#1
16#0
16#199B
16#0
16#199B
16#55
16#55
16#1
16#1
16#0
16#66D
16#0
16#66D
-
-
16#0
16#0
off
off
0 mA
5 mA
16#AA
16#AA
16#1
16#1
16#0
16#199B
16#0
16#199B
16#AA
16#AA
16#1
16#1
16#0
16#665
16#0
16#665
-
-
16#0
16#0
off
off
Connectable components
9.3 PP 72/48D 2/2A PN
Voltage ±10 V
10 V
16#55
16#1
16#6666
16#6666
16#55
16#1
16#19B5
16#19B5
-
16#0
off
Current 20 mA
20 mA
16#AA
16#1
16#6666
16#6666
16#AA
16#1
16#1996
16#1996
-
16#0
off
12 V
16#55
16#1
16#7AE1
16#7AE1
16#55
16#1
16#0
16#0
16#2
16#7
on
Deactivating/
activating
22 mA
16#AA
16#1
16#70A5
16#70A5
16#AA
16#81
16#0
16#0
16#2
16#7
on
Deactivating/
activating
141