Digital outputs
● Characteristics
● Terminal assignment for the digital outputs:
● Technical data:
Table 9-46
Digital outputs
High-level voltage (U
Output current I
Voltage with low level (U
Leakage current at low level
Signal delay time T
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
– No galvanic isolation.
– Protection against: Short-circuit, overtemperature, and loss of ground.
– Automatic disconnection in case of undervoltage.
The following figure shows an example of the terminal assignment for the digital outputs
on connector X111. Connectors X222 and X333 are assigned analogously.
:
:
:
:
Figure 9-18
Terminal assignment for the digital outputs
NOTICE
Damage to the module
If the outputs are overloaded, the heat can melt the contacts.
Therefore, for a demand factor of 100%, a max. current of I
X333: Pin 2, must not be exceeded.
Electrical specification of the digital outputs
)
H
OUT
)
L
PHL
1
(M)
min.
V
- 3 V
CC
-
-
-
-
Connectable components
9.3 PP 72/48D 2/2A PN
= 0.25 A at X111, X222,
out
Standard
max.
V
1)
CC
-
250 mA
2)
-
-
50 μA
400 μA
0.5 ms
-
nominal
24 V
-
Output open
-
-
129