Installation
Instructions
ADVANCE
PLANNING
Ductwork
Plamah_g
• This
hood
may
be vented
vertically
through
upper
cabinets,
soffit
or ceiling.
A duct
transition
piece
is
supplied
fin" vertical
exhaust.
Use
locally
supplied
elbows
to vent
horizontally
through
the
rear
wall.
See
page
13.
• Determine
the
exact
location
of the
vent
hood,
Phm
tile
route
fin" venting
exhaust
to tile
outdoors.
• Use
tile
shortest
and
straightest
duct
route
possible.
For
satislhctm
T l)eflbrmance,
duct
_un
should
not
exceed
1 O0 tL equivalent
length
tin" any
duct
configurations.
• Refer
to "Duct
Fittings"
chart
to compute
tile maximmn
permissible
length
fin" duct
itlns
to tile
outdoors.
• Use metal
ductwork
only:
• A transition
piece
fin" 7" rotmd
duct
is supplied.
Lrse
7" round
duct
or you
may
use
3-1/4"
x 12" rectangular.
• Install
a wall
cap
or roof
cap
with
damper
at the
exterior
opening.
Order
tile wall
or roof
cap
and
any
transition
needed
in adwmce.
Kit - JXDW1
Order
kitJXDW1
if your
installation
requires
horizontal
ducfing
fix)m
the
top of the hood
through
the back
_Jll
and:
• You
have
an
S tL ceiling
and
need
to use a JXCH
Series Chimney Cover, or
• You
have
a 12" cabinet
or 12" sottit
that
the
hood
is to
be mo/mted
beneath.
Tiffs
kit provides
a duct
transition
fl'om
7" to/rod
to
3V/' x ] 0" rectangular
for
through-the-wall
venting.
Wall
Framhlg
for
Adequate
Support
• This
vent
hood
is heavy.
Adequate
st_ ucmral
sui_port
must
be provided.
Tile
hood
must
be
secured
to
vertical
studs
in the
wall.
See
page
14.
• We strongly
recommend
that
the
vent
hood
with
duct
cover
be on
site befl)re
final
fl'aming
and
wall
finishing.
This
will also
hel I) to accurately
locate
the
ductwork
and
electrical
service.
DUCT FITTINGS
Follow
these
guidelines
fin" proper
duct
sizing
in tile
ductino
charts.
DUCTING CHART - 30" Models
Equivalent Length in Feet For 7" Round Duct
Z
0
25
50
75
100
125
150
600
500
E
400
200
7" Round%° Elbow= 14ft.
7"RoofCap= 39 ft.
MAXIMUM
DUCT
LENGTH:
7" dia. duct should
not
exceed
100 equivalent
feet.
DECORATIVE
DUCT COVERS
A decorative
duct
cover
is available.
Tile
duct
cover
conceals
tile
ductwork
_tmning
fl'om
tile
top
of tile
hood
to tile
ceiling
or soffit.
Tile
duct
cover
will fit
8 tL to 10 tL ceiling
heights.
See
page
12 tot
derails.
POWER SUPPLY
IMP(-)RTANT-
(Please
read
careflfll))
WARNING:
FOIl PERSONAl, SAFETY, THIS APPHANCE
MUST
BE PROPERI,Y GROUNDED.
Remoxe
house
fllse or open
circuit
breaker
before
beginning
installation.
Do not use an extension
cord or adapter
plug with
this appliance.
Follow National
Electrical
Code
or
prexailing
local
codes and
ordinances.
Electrical
supply
Tiffs
vent
hood
must
be suI_plied
with
120V,
60Hz,
and
cmmected
to an individual,
properly
grounded
branch
circuit,
and
protected
by a 15 or 20 amp
circuit
breaker
or trine
delay
filse.
• Wiring
must
be
2 wire
with
gro/md.
• If the
electrical
sui)ply
does
not
meet
the
above
requirements,
call a licensed
electrician
befln'e
proceeding.
• Route
house
wiring
as close
to tile
installation
location as possible in the ceiling, sottit or wall.
See
page
13 fin" details.
• Connect
the
wiring
to the
house
wiring
in
accordance
with
local
codes.
Grounding
instructions
Tile
gro/mding
conductor
must
be connected
to a
gro/mded
metal,
pemmnent
wiring
system,
or an
equil)ment-grom_ding
terminal
or lead
on tile
hood.
WARNING:
The
improper
connection
of
tile
equii)ment-grounding
conductor
can
result
in a
risk
of electric
shock.
Check
with
a qualified
electrician
or service
representative
if you
are
in doubt
whether
tile
appliance
is properly
gro/mded.