DETERMINE
HOOD, DUCTWORK
AND WiRiNG
LOCATIONS
• Keep the wood support
piece
and
its screws fi)r
later installation.
Do not discard.
• Measure
desired
distance
fl'om
tile bottom
of the
hood
to the cooking
surfhce,
24" rain.
to 36" Max.
Refbr
to the previous
page
if the accesso W duct cover
will be used.
• Use a level to draw a horizontal
line indicating
the
bottom
of the hood.
• Use a level to draw the cooktop
centerline
location.
• Measure
15-3/8"
up from
the horizontal
line for the
bottom
of tile hood.
Draw another
horizontal
line.
• Measure
18" up fi'om the line ti)r the bottom
of the
hood,
draw another
horizontal
line to indicate
the
top of the hood.
FOR VERTICAIL
(Straight
Up) DUCTING:
* If venting
out the ceiling,
extend
the centerline
forward
on the ceiling.
- Measure
6-7/8"
fl'om drywall
to mark
centerline
for a
7-1/2"
dia. duct hole on the ceiling.
- If dr3avall is not present,
add drywall
thickness
to the
6-7/8"
dimension.
Venting
through
a soffit or upper
cabinet.
* Follow
tile same
procedure
fl)r ceiling
ducting
to cut
the 7-1/2"
dia. hole through
the top of the cabinet
or
softit.
* See Step 4, page
15 for details
to cut opening
fl)r duct
transition.
,,
, /FOR CEILING
6-7/8 ......
_!VENT
DUCTING
ben_enme
I0
wall
)_.;
cI,
/J
c.._.
/:
Ebctrica,
7-1/2"Dia. Hob_
,CL
\
I
_.
.Centeriine
8,, Min. Above
FOR WALLVENTDUCT/[
Topof Hood
Topof Hood
Bottomof Hood
1
1
Wood
Support
Ebctrical
15-3/8"
FOR DUCTING
THROUGH
REAR WALL:
* Measure
the supplied
duct transition
with any straight
run length
of duct
used, plus 90 ° elbow
height.
Draw a
horizontal
line on the wall intersecting
the centerline.
House Wiring
Location:
* Thejmwtion
box is fhstened
to tile back ot the hood
on the right
side. See illustrations
tot hood
knockout
locations.
Note:
Thejmlction
box can be relocated
to the inside
top of the hood.
House
wiring
may enter
thejmlction
box fl'om the rear
or the top of the hood
at the right
side.
To route
house
wiring
through
the ceiling
or soffit:
-Cut
a hole approxinmtely
1" dia., 5-7/8"fl_rward
on
tile ceiling,
11-1/8"
to the right of the centerline
fl_r
30" models.
To route
house
wiring
through
the wall:
-Cut
a hole approximately
1" dia., 10-1 / 16 "down
fi'om the top of the hood,
ll-1/8"to
the right
of the
centerline
for 30" models.
* Remove
top or rear knockout
depending
on your
installation.
* Install
strain
relief
onto
back or top of hood.
11-1/8"for 30" models
Knockout
Locations
13