Fault Close Operation Speed Curve In Encoder Mode - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

Fault CLOSE operation speed curve in encoder mode

OPEN hold
operation
Frequency
7
DOOR region
OPEN command
signal terminal
No.1
CLOSE command
signal terminal
No.2
Safety sensor
signal No.5
OPEN arrival
signal terminal
No.3
CLOSE arrival
signal terminal
No.4
100%
DOOR
position
0%
Fault CLOSE operation speed curve in encoder mode
OPEN hold
operation
Frequency
7
DOOR region
OPEN command
signal terminal
No.1
CLOSE command
signal terminal
No.2
Fault CLOSE
command signal
terminal No.5
OPEN arrival
signal terminal
No.3
CLOSE arrival
signal terminal
No.4
100%
DOOR
position
0%
8
9
10
8
9
10
P80 safety sensor function select Setting value is 1
Fault CLOSE operation
12
11
safety sensor function select Setting value is 2
Fault CLOSE operation
12
11
CLOSE hold operation
hold wait time
(d46)
Hold operation
13
0
CLOSE hold
operation
Hold wait
time(d46) Hold operation
13
0
CLOSE
arrival hold
current d41
CLOSE
arrival hold
current d41
69