Output Function Summary Table – This table shows all functions for the logical outputs
(terminals [11], [12] and [AL]) at a glance. Detailed descriptions of these functions, related
parameters and settings, and example wiring diagrams are in "Using Intelligent Output
Terminals" on page 39.
Option
Terminal
Code
Symbol
00
RUN
Run Signal
01
FA1
Frequency Arrival Type
1–Constant Speed
02
FA2
Frequency Arrival Type
2–Over frequency
03
OL
Overload Advance
Notice Signal 1
04
OD
Output Deviation
for PID Control
05
AL
Alarm Signal
06
FA3
Frequency Arrival Type
3–Set frequency
07
OTQ
Over/under Torque
Signal
09
UV
Undervoltage
10
TRQ
Torque Limited Signal
11
RNT
Run Time Expired
12
ONT
Power ON time Expired
13
THM
Thermal Warning
19
BRK
Brake Release Signal
20
BER
Brake Error Signal
Output Function Summary Table
Function Name
ON
When the inverter is in Run Mode
OFF
When the inverter is in Stop Mode
ON
When output to motor is at the set frequency
OFF
When output to motor is OFF, or in any
acceleration or deceleration ramp
ON
When output to motor is at or above the set freq,
even if in accel (C042) or decel (C043) ramps
OFF
When output to motor is OFF,
or at a level below the set frequency
ON
When output current is more than the set
threshold (C041) for the overload signal
OFF
When output current is less than the set threshold
for the deviation signal
ON
When PID error is more than the set threshold for
the deviation signal
OFF
When PID error is less than the set threshold for
the deviation signal
ON
When an alarm signal has occurred and has not
been cleared
OFF
When no alarm has occurred since the last
cleaning of alarm(s)
ON
When output to motor is at the set frequency,
during accel (C042) and decel (C043).
OFF
When output to motor is OFF,
or is not at a level of the set frequency
ON
Estimated motor torque exceeds
the specified level
OFF
Estimated motor torque is lower than
the specified level
ON
Inverter is in Undervoltage
OFF
Inverter is not in Undervoltage
ON
Torque limit function is executing
OFF
Torque limit function is not executing
ON
Total running time of the inverter exceeds
the specified value
OFF
Total running time of the inverter does not exceed
the specified value
ON
Total power ON time of the inverter exceeds
the specified value
OFF
Total power ON time of the inverter does not
exceed the specified value
ON
Accumulated thermal count exceeds
the C061 set value
OFF
Accumulated thermal count does not exceed the
C061 set value
ON
Output for brake release
OFF
No action for brake
ON
Brake error has occurred
OFF
Brake performance is normal
84