CHAPTER 2. MMC Programming

[ 200] OPEN CUSTOMER PROGRAMMING

5 7 B
Used to open(enable) and close(disable) customer-level programming. If programming is
not opened and an attempt is made to access a system MMC, the error message [NOT
PERMIT] will be displayed. A four digits passcode is required to access this MMC. Each
digit can be 0-9. When opened, this MMC enables access to all MMCs allowed in MMC
802, Customer Access MMC Number.
No
Mode
0
DISABLE
1
ENABLE
D EFAULT DATA
3 6 3 B
DISABLE
A CTION
3 6 4 B
1) Press Transfer button and enter 200.
Display shows:
2) Enter passcode.
Correct code shows.
Incorrect code shows.
3) Press Volume button arrow key to select ENABLE
or DISABLE and press Right Soft button.
OR
Dial 1 for ENABLE or 0 for DISABLE.
4) Press Speaker button to advance MMC entry level
and press Volume button to select MMC.
OR
Enter MMC number and press Right Soft button
to enter MMC.
5) Press Transfer button to exit.
R ELATED ITEMS
3 6 5 B
MMC 201
MMC 501
MMC 802
2-44
Description
Open(enable) customer-level programming.
Close(disable) customer-level programming.
CHANGE CUSTOMER PASSCODE
SYSTEM-WIDE TIMERS
CUSTOMER ACCESS MMC NUMBER
DISPLAY
ENABLE CUS.PROG.
PASSCODE:
ENABLE CUS.PROG.
PASSCODE:
ENABLE CUS.PROG.
DISABLE
ENABLE CUS.PROG.
PASSCODE ERROR
ENABLE CUS.PROG.
ENABLE
2
0 1:CUS.PASSCODE
U
U
SELECT PROG. ID
Samsung Business Communications