Mitsubishi Electric MELSEC IQ-R series Reference Manual page 93

Programmable controller
Hide thumbs Also See for MELSEC IQ-R series:
Table of Contents

Advertisement

Communication example (Reading word device)
Read values of T100 to T102. (Subcommand: for MELSEC-Q/L series)
T100 = 4660 (1234H), T101 = 2 (2H), T102 = 7663 (1DEFH) are stored.
■Data communication in ASCII code
(Request data)
Subcommand
0
4
0
1
0
0
0
30
34
30
31
30
30
30
H
H
H
H
H
H
H
(Response data)
1
2
3
4
0
0
0
31
32
33
34
30
30
30
H
H
H
H
H
H
H
T100
T101
■Data communication in binary code
(Request data)
Device
Subcommand
Head device
number
01
04
00
00
64
00
00
H
H
H
H
H
H
H
(Response data)
34
12
02
00
EF
1D
H
H
H
H
H
H
T100
T101
T102
Device
Head device number
code
0
T
N
0
0
0
1
30
54
4E
30
30
30
31
30
H
H
H
H
H
H
H
2
1
D
E
F
32
31
44
45
46
H
H
H
H
H
T102
code
Number of
device points
C2
03
00
H
H
H
Number of device points
0
0
0
0
0
3
30
30
30
30
33
H
H
H
H
H
H
8 DEVICE ACCESS
8.2 Batch Read and Write
8
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsecq seriesMelsec l series