Keypad & Readers Setup; Dip Switch Address Select; Rotary Switch Address Select - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

In version 2.14, this has been corrected so that the
RED status led will turn off when the user turns off the
area via the keypad regardless of any trouble events
being present.
K E Y PA D & R E A D E R S S E T U P
The control panel can have a maximum of 16 keypads
and/or readers connected via the LAN terminals. Each
keypad or reader must be set to a unique address before
they will operate.
Each keypad or reader needs to be assigned to a home
area via MENU 6-1-3. This sets the area the keypad or
reader will display and control by default. Keypads and
readers can be locked to a home area or allowed to roam
or move between areas. At factory default, the home area
is factory default to operate Area 1.
Set each keypad or reader address using "Table 7: DIP
Switch Address Settings" on page 2-7 and "Table 8:
Rotary Switch Address Settings" on page 2-7 as a guide.
Only 1 keypad can be assigned to each address. All
i
keypads are supplied from the factory set to address
Note
1. (OFF-OFF-OFF-OFF).
D I P S W I TC H A D D R E S S S E L E C T
Figure 10: Keypad DIP Switch Address Settings
DIP Switch Address Settings
Keypad/Reader N
o
1
Off
2
On
3
Off
4
On
5
Off
6
On
7
Off
8
On
9
Off
10
On
11
Off
12
On
13
Off
14
On
15
Off
16
On
Table 7: DIP Switch Address Settings
Bosch Security Systems 07/14 BLCC610I
4
S1
S2
S3
Off
Off
Off
Off
On
Off
On
Off
Off
On
Off
On
On
On
On
On
Off
Off
Off
Off
On
Off
On
Off
Off
On
Off
On
On
On
On
On
Solution 6000
R OTA R Y S W I TC H A D D R E S S S E L E C T
Keypads and readers fitted to the system must be as-
signed a unique address on the LAN. Some keypads and
readers include a rotary address switch for quick selec-
tion.
The following table shows how to set the address set-
ting for each keypad and reader, as well as the number of
devices the panel can support.
Rotary Switch Address Settings
Address Number
Table 8: Rotary Switch Address Settings
S4
Off
Off
Off
Off
Figure 11: Rotary Swich Address Settings
Off
Off
Off
Off
On
On
On
On
On
On
On
On
Installation Manual
Installing the Hardware
Keypad/Reader N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
o
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
2-7

Hide quick links: