6.10.2
Reloading the HiPath ComScendo Service (if required)
Reloading the HiPath ComScendo Service means deleting the files hicom.pds and hi-
com.pds.bak.
These files contain the complete data description of the HiPath 5000 with emulated HG 1500
boards. This includes:
customer data
●
trace
●
error history
●
call charge data
●
status data
●
The directory in which the two PDS files are to be stored is defined when the HiPath 5000 soft-
ware is installed (setup). The two PDS files are created when the HiPath 5000 is started for the
first time.
The PDS files must not be modified, as reading of the files using conventional tools
>
and interpretation of the content is not possible without specialist knowledge.
Procedure
1.
Call up the HiPath 5000 State Viewer with Start/Programs/HiPath/HiPath 5000
State Viewer.
2.
Exit the HiPath 5000 server by clicking Stop Server.
3.
Delete the files hicom.pds and hicom.pds.bak.
Note: This restores the default settings for the entire content of the customer database. All
country and customer-specific settings are lost.
4.
Start the HiPath 5000 server by clicking Start Server in the HiPath 5000 State Viewer.
When operating correctly, the server state is shown as "Running"; "status indicators are green"
is shown for all services.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
HiPath 5000 Startup and Administration
Perform HiPath 5000 Basic Configuration
start_h5.fm
6-51