Siemens HiPath 5000 Service Manual page 649

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

Procedure for mounting the MDFU on the wall
Step
1.
Use the template to drill the holes.
2.
Insert the wall anchors and screw in the screws, leaving 5 mm projecting.
3.
Remove the housing cover and mount the MDFU-E on the brackets.
4.
Tighten the screws through the holes.
Layout and dimensions of the MDFU
1
2
3
4
5
6
7
8
9
Special built-in comps.
Figure 4-95
MDFU - Layout and Dimensions (367.0 x 328.8 x 125.4 mm) (not for U.S.)
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
9 slots (9 x 30 mm)
2 x PFT1
or
1 x PFT4
System side
Activity
328.8
Installing HiPath 3000
Jumpering
Channel
Line network
inst_h3.fm
4-171

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800

Table of Contents